On-line monitoring of ammonia in water is of increasing importance due to the growing emphasis on nutrient reduction in lakes, streams, and estuaries. This flexible monitor is especially suited to environmental applications such as river inlet monitoring or waste water final effluent, plus the Q46N also measures free and total ammonia and is designed for the control of chloramination processes.
Alternative, simple direct measuring sensors have not proven sufficiently reliable and rather complicated systems have been developed to address the measurement problem. These systems can be used but require substantial maintenance and are expensive to purchase.
ATi has developed a new approach to on-line monitoring of ammonia that is easier to operate and less expensive than competitive systems, but with the reliability you need.
• Fast response time for real-time ammonia measurement • Simple chemical system uses inexpensive reagents • Display of Free Ammonia, Monochloramine, and Total Ammonia for chloramination systems • Automatic response verification for ammonia breakthrough applications • Multiple digital communication options: Profibus, Modbus or Ethernet
Applications
The Q46N ammonia monitor is available for a wide range of applications including:
Chloraminated potable water
Wastewater effluent
Potable water intake
Ammonia chillers
Aquariums
Fish farms
Operation
Ammonia measurement is accomplished by the addition of three reagents, each of which is fed using a multichannel peristaltic pump. A stabilizer chemical is injected first to stop calcium precipitation in the tubing. After that, a solution containing free chlorine is injected which results in the conversion of ammonia to monochloramine.
The third reagent added quenches the above reaction by removing the excess free chlorine. This ensures that free ammonia in the sample stream is converted to monochloramine, and dichloramine formation does not occur. Once chloramine formation is complete, the sample is temperature stabilised and pumped to a flowcell containing a special amperometric membraned sensor. This sensor measures the monochloramine formed in the chemical system and produces a highly linear output that is amplified and displayed in the monitor.
Chloramination System Monitoring
Chloramination in potable water treatment has become common, especially in utilities with large distribution systems. The use of chloramines to reduce disinfection by-products and to provide disinfectant protection throughout a large pipe network has proven useful but does present potential water quality problems if not controlled properly .A carefully controlled chloramination system will result in the conversion of all free chlorine to monochloramine with only a slight excess of ammonia. This excess ammonia, called ‘free ammonia’, should be kept as low as possible to avoid the formation of nitrites and nitrates in the distribution system.
Minimising the free ammonia concentration requires the accurate measurement of free chlorine to pace the ammonia addition, and also requires an accurate measurement of residual free ammonia. A special version of the Q46N Ammonia Monitor provides the capability of monitoring free ammonia by continuously measuring both total ammonia and monochloramine concentrations. Free ammonia concentration is then derived from these values. Two sensors integrated into the Auto-Chem chemistry system provide the required measurements. A sensor located in the inlet assembly measures monochloramine concentration in the chloraminated water. After addition of reagents, a second sensor measures the total ammonia concentration. The electronic monitor subtracts the monochloramine ammonia from the total ammonia and displays the free ammonia value.
Ammonia Response Verification
Total ammonia monitors are frequently used in applications where ammonia is not normally present. Under normal operating conditions, refrigeration systems utilising ammonia chillers have no ammonia in the process water. An ammonia monitor would display 0 PPM until a leak occurs. The Q46N Total Ammonia Monitor provides an automatic response verification system that confirms that the system is functioning properly. At user programmed intervals, a 1 PPM ammonia solution is introduced into the sample stream and the response is monitored to confirm the system is functioning properly. Outputs and alarms are inhibited during the test and an alarm is generated if the unit fails to respond. This system is not used for applications where ammonia is normally present but is very useful for ammonia breakthrough applications.
A global company with a caring culture. We have a team of experts on hand to help with any product or support query you may have. Contact us and experience ATi’s exemplary customer support.
Stay up to date with our latest innovations, solutions, projects and announcements by signing up to our newsletter.
This Website Uses Cookies
By clicking "Accept All" you consent to the use of 1st and 3rd party cookies (or similar) in order to enhance your overall web browsing experience, provide you with ads tailored to your interests, and allow us to measure our audience and collect other analytical data about the use of our website. By using this website, you accept our Terms of Use. To edit your cookie preferences, select “Cookie Preference Center” below. For more information about how we use cookies, please visit our Cookie Policy.
This website uses cookies to improve your experience while you navigate through the website. Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may affect your browsing experience.