IsoMon, dual-channel Hydrogen Peroxide monitoring

ATi’s IsoMon dual-channel gas detection system is specifically designed for monitoring complete decontamination cycles from start to finish, in isolators or other chambers, using hydrogen peroxide sterilisation (H2O2).

This unique system was primarily developed to address the needs of the medical and pharmaceutical industries, but can also be used within food packaging, biological, defence and industrial settings.

IsoMon is a fist-of-its-kind gas detector that allows both high and low value measurement of hydrogen peroxide levels, providing users with reliable validation data regarding the sterilization of aseptic environments. The instrument is designed to pull samples from an enclosed space, delivering them to two separate measuring cells, one for high concentration and the other for low concentration.

Hydrogen Peroxide Gas

ATi are one of the only gas sensor companies in  the world that manufacture an accurate sensor  that can be used to protect staff. H2O2 is released  into the air during the decontamination process (fogging) and should be monitored as part of your Quality Controls Programs. Rooms, surfaces and equipment can be sterilized multiple times per day with higher levels of H2O2  than ever before, increasing the risk to those working  close to them.

Monitoring H2O2  levels enables you to ensure sterile levels subsequently drop to safe, ambient levels post sterilisation. This continuous monitoring allows you to validate and demonstrate that the vapour in the air is safe, posing no risk to staff and patients. Generating the right amount of gas is vital for efficacy over prolonged periods. It is therefore essential to understand and accurately monitor H2O2 levels with a pre-calibrated monitor.

How does it work?

The IsoMon monitoring system draws the sample through Teflon® lined tubing, using an internal two-channel sample pump, with each pump head providing flow to a separate sensor. A common sample inlet port is provided, but an integral solenoid valve controls sample delivery to the low-concentration sensor.

IsoMon

The solenoid valve is controlled by the high-concentration monitor to avoid saturation of the low-concentration sensor. The solenoid is activated when the measured value on the high concentration sensor reaches 30ppm and will reset at 28ppm. When the solenoid switches, ambient air is drawn into the low-concentration unit to ensure that it is ready to operate when gas or vapour levels fall back to a lower level. This is done to ensure that the low level sensor is not saturated by long exposure at high concentration.

The high-concentration measuring channel can measure to a maximum of 2000ppm. However, it is possible to set the data logging and analogue output range to a smaller, full-scale value. As shipped from the factory, the high-concentration channel will be programmed for a logging range of 0-1000ppm. With this adjustment, the display will indicate values up to 2000ppm, but the internal data logger will not log values above 1000ppm. This is done to improve data-logger resolution when  the instrument is measuring at lower levels.  The low-concentration channel has a maximum measuring value of 200ppm, but is set for a logging range of 0-20ppm as the default.

As with the high-concentration channel, the  low-concentration channel can be programmed for any full-scale logging range within the limits of  the sensor.

ATi H10 smart gas sensor

The sensor used for hydrogen peroxide monitoring is the ATi H10 smart gas sensor with integral memory. The sensor contains calibration data, specific only to the sensor, and can easily be returned to ATi for recalibration. This eliminates the need for users to set up special calibration equipment. Standby sensors with up-to-date calibrations can be quickly inserted into the individual channels when installed.

Data logging of concentrations is done in each measuring channel separately. The accumulated data may be downloaded to a PC using the RS-232 connection. Data is transferred to files for use in Microsoft Excel or other data handling programs. Data intervals of 1 second up to 60 seconds may be selected, with data storage from 11 days to more than 400 days depending on the storage interval. While the IsoMon is a transportable device designed for use in a variety of locations, external power is required to operate the monitor.

Featured Article

Related content



News icon
News
Badger Meter Enhances Smart Water Capabilities With Acquisit…

Badger Meter continues to invest in its industry-leading smart water offerings. and is pleased to announce the acquisition of Syrinix, Ltd, a privately held provider of intelligent water monitoring solutions.

Read
News icon
News
Reduce excess chemical overfeed with the Q46S Residual Sulfi…

The removal of chlorine before discharge to the environment from clean water and also waste water effluent is common practice…

Read
News icon
News
Get Street Smart with ATi’s MetriNet street-level telemetr…

Water quality monitoring has just got smarter with ATi’s latest innovation, the exclusive smart multi-parameter, street-level telemetry bollard.

Read


A team of experts, ready to help

A global company with a caring culture. We have a team of experts on hand to help with any product or support query you may have. Contact us and experience ATi’s exemplary customer support.

Get in touch